Abstract
ABSTRACT In resistance spot welding (RSW) joints of austenitic stainless steel (ASS), a small-scale electrochemical cell (minicell) was used for assessing individually, on each of the three welding zones, of size less than 1000 µm (fusion zone (FZ), heat affected zone (HAZ) and base metal (BM)), the combined effect of a RSW process and post-welding sensitisation on the degree of sensitisation (DOS). The results show that the three welding zones have different microstructures that make each of them respond differently to post-welding sensitisation. The DOS varies with post-welding sensitisation time in all three welding zones, but it varies at a different rate in each welding zone (the highest rate in the FZ). This variation is due to the fact that when the DOS reaches a certain level, which is observed when plotting the reactivation charge (Qr) versus the post-welding sensitisation time, a microstructural regeneration occurs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.