Abstract
Photoacoustic spectroscopy was used to measure the pulse duration dependence of the XeCl laser ablation of polyimide, polyethylene terephthalate, and post-mortem human aorta. It was observed that the ablation threshold exhibited only a weak dependence on pulse duration. Photoablation etch depth measurements of polyimide as a function of XeCl laser fluence indicated that over a practical etch depth range of 0.1 to 1 μm per laser pulse the etch depth was independent of the pulse duration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.