Abstract

The radial variation of the heat transfer coefficient across the bed width, including the effect of fins and fin shapes (surface roughness), on the heat transfer characteristics in the lean phase region of a circulating fluidized bed riser column are investigated. Three test sections (bare horizontal tube, V-fin tube and square fin tube) are employed for the investigation. The experimental unit consists of a riser column of 102×102 mm in bed cross-section, 5·25 m in height with a return leg of the same dimensions, and both made up of plexiglas columns. For the same operating conditions, the provision of fins results in a drop in heat transfer coefficient, but increases total heat transfer owing to increased surface area. The present experimental data are compared with published literature and good agreement has been observed. The experimental data also corresponds to the two-zone hydrodynamics (i.e. the core–annulus structure) of a circulating fluidized bed. © 1997 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call