Abstract

The axial and radial variation of the heat transfer coefficient in a circulating fluidized bed riser column, and the effect of operating parameters thereon, are investigated. The experimental set-up consists of a riser column of 102 mm×102 mm in bed cross-section, 5·25 m in height with a return leg of the same dimensions. The unit is fabricated with plexiglass columns of 0·6 m in length which are interchangeable with one another. Two axial heat transfer test sections of 102 mm×102 mm in cross-section, 500 mm in height, and made of mild steel, are employed for the axial heat transfer study and one horizontal tube section of 22·5 mm OD made of mild steel is employed for the radial heat transfer study. The primary air velocity is varied between 4·21 and 7·30 m s−1. Local sand of mean size (dp) 248 μm is used as the bed material. One empirical model with the help of dimensional analysis has been proposed to predict the heat transfer coefficient to a bare horizontal tube in a CFB riser column and the model results are validated with the experimental data; good agreement has been observed. © 1997 John Wiley & Sons, Ltd.