Abstract

In this study, the performance of a commercial low-pressure reverse osmosis membrane system (TW30-1812-100) was evaluated for 2-chlorophenol removal from wastewaters. The influence of various operational conditions and system specifications such as feed pressure, feed flow rate, pH, and concentration on 2-chlorophenol rejection was investigated. The results showed that at optimum conditions (200 ppm feed concentration, 408.1 kPa feed pressure, pH 10, and 1.953 × 10−5 m3/s feed flow rate) 79% rejection was attainable. In addition, it was found that at the feed pH was the most effective parameter on 2-chlorophenol rejection. The rejection was increased with feed pH. An increase of feed flow rate had a positive effect on 2-chlorophenol rejection. The study of the influence of feed pressure showed a maximum critical pressure for rejection. However, the study of feed concentration on 2-chlorophenol rejection did not show a clear trend.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.