Abstract
The slow phase eye velocity (SPEV) and duration of post-rotatory nystagmus (PRN) were studied in squirrel monkeys (Saimiri sciureus) after a ramp speed rotation (0-200 degrees/sec, with 1 degree/sec2 angular acceleration). When the results were compared between straight upright vertical rotation, 9 degrees tilt rotation, and 18 degrees tilt rotation, faster decay both in SPEV and in duration was found in the tilt rotation situations. Difference in nystagmic decay curves by tilting rotation axis could be from the convergence of macula-semicircular canal inputs. Subsequently bilateral macular ablation (two-stage) was performed. The difference in nystagmus decay curves between three different rotations was reduced; therefore, the change of gravity direction perceived through gravity receptors other than macular endorgans was minimal and did not produce a difference in three different rotations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.