Abstract
The aim of this study was to investigate the effects of occlusal form of abutment, occlusal thickness of monolithic zirconia crowns (MZC), and cement type on the fracture load of MZC. Abutments were prepared with 2 types of occlusal forms: groove-type and flat-type. These were designed so that thickness at the central fissure region of MZC was 0.3, 0.5, or 0.7 mm. Glass ionomer cement and resin cement were used to lute MZC to their corresponding abutment. Fracture load was determined using a universal testing machine. As a result, groove-type abutment had lower fracture load compared to flat-type abutment; however, the decline in strength was smaller when resin cement was used. Additionally, specimens with larger occlusal thickness had greater fracture load regardless of groove or cement-type. The fracture of MZC occurred on the central fissure region of MZC except for 0.7 mm groove-type MZC luted with resin cement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.