Abstract

Neon glow discharge cleaning was firstly attempted in Large Helical Device (LHD) instead of He glow discharge to remove hydrogen neutrals and to control the ion density, ni. The Ne glow discharge continued for 8 hours overnight after a three-day experiment. At the second night Hα emission became weaker than the emission usually observed in the He glow discharge. A clear reduction of the hydrogen influx was also observed in neutral beam injection (NBI) discharges with Ne puff, whereas the neon recycling was strongly enhanced with appearance of a flat density profile. As a result, the lowest density limit was further reduced down to 0.2 × 1013 cm-3. The use of Ar puff formed a peaked density profile with a high Ti of 7 keV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.