Abstract

ObjectiveTo investigate the effect of narrow paravisceral aorta (NPA) on target vessel instability (TVI) after fenestrated-branched endovascular aortic repair. MethodsWe conducted a single-center retrospective study (2014-2023) of patients treated by fenestrated-branched endovascular aortic repair for thoracoabdominal aortic aneurysms (TAAA) or pararenal aortic aneurysms. The paravisceral aorta was defined as the aortic segment limited by the diaphragmatic hiatus proximally and the emergence of lower renal artery distally, and was considered “narrow” in case of a minimum inner diameter of <25 mm. The minimum aortic diameter, location, longitudinal extension, angulation, calcification, and thrombus thickness of NPA were evaluated at the preoperative computed tomography angiogram. End points were 30-day technical success and freedom from TVI. ResultsThere were 142 patients with JRAA/pararenal aortic aneurysm (n = 85 [59%]) and extent IV (n = 24 [17%]) or extent I-III (n = 33 [23%]) TAAA, with 513 target arteries successfully incorporated through a fenestration (n = 294 [57%]) or directional branch (n = 219 [43%]). A NPA was present in 95 patients (70%), 73 (86%) treated by fenestrated endovascular aortic repair (FEVAR) and 22 (39%) by branched endovascular aortic repair (BEVAR). The overall 30-day mortality was 2% and technical success was 99%, without differences between NPA and non-NPA (P = .99). Kaplan-Meier estimated freedom from TVI at 4 years was 82%, 81% (95% CI, 75-95) in patients with a NPA and 80% (95% CI, 68-94) and in those without NPA (P = .220). The result was maintained for both FEVAR (NPA: 81% [95% CI, 62-88]; non-NPA: 76% [95% CI, 60-99]; P = .870) and BEVAR (NPA: 77% [95% CI, 69-99]; non-NPA: 80% [95% confidence interval (CI) 66-99]; P = .100). After multivariate analysis, the concomitant presence of a NPA <20 mm and angulation of >30° was significantly associated with TVI in FEVAR (HR, 3.21; 95% CI, 1.03-48.70; P = .036), being the result mostly driven by target vessel occlusion. In BEVAR, a NPA diameter of <25 mm was not associated with TVI (HR, 2.02; 95% CI, 0.59-5.23; P = .948); after multivariate analysis, the use of outer branches in case of a NPA longitudinal extension of >25 mm (hazard ratio [HR], 3.02; 95% CI, 1.01-36.33; P = .040) and NPA severe calcification (HR, 1.70; 95% CI, 1.00-22.42; P = .048) were associated with a higher chance for TVI. ConclusionsFEVAR and BEVAR are both feasible in cases of NPA and provide satisfactory target vessels durability. The use of outer branches should be avoided in cases with an inner aortic diameter of <25 mm with a longitudinal extension of >25 mm or moderate to severe NPA calcifications. In FEVAR, bridging stent patency may be negatively influenced by NPA of <20 mm in association with aortic angulation of >30°.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.