Abstract

The effect of magnetic field with different intensities on fatigue life of AISI 4140 steel has been investigated. For this purpose, unnotched and notched specimens were prepared from AISI 4140 steel. It was obtained that when the magnetic field especially was applied to the specimens at the stage of fatigue crack initiation, the fatigue life improved by reason of delaying formation time of slip bands due to regular direction and distribution of magnetic domains. And, it was observed that magnetic field was applied from the beginning of fatigue test up to occur the fatigue fracture, it was detrimental on the fatigue life because of over heating of the specimens.