Abstract
The effect of loading on microleakage and microtensile bond strength of MOD composite restorations bonded with either self-etching or etch-and-rinse adhesive was investigated. MOD cavities were prepared in 28 extracted molar teeth. 14 teeth were bonded with a one-step self-etching adhesive (G-Bond) and 14 with an etch-and-rinse adhesive (Optibond Solo Plus) then restored with resin composite. For each adhesive, 7 teeth were loaded and 7 unloaded (controls). Loading was achieved with an axial force of 80 N at 2.5 cycles/s for 250,000 cycles. All the teeth were stored in 0.25% rhodamine solution for 24 h and sectioned in a bucco-lingual direction at the proximal boxes to examine microleakage then further sliced mesiodistally into beams for the μTBS test. Failure modes were determined using confocal and scanning electron microscopy. ANOVA assessed the effect of loading on microleakage and bond strength. After loading, restorations bonded with G-Bond exhibited significantly greater dye penetration compared to Optibond Solo Plus at both the axial walls and cavity floor. On the other hand, loading significantly reduced the μTBS of Optibond Solo Plus, whereas it had no significant effect on the μTBS of G-Bond.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.