Abstract
An experiment was performed in a wide range of core flooding rate to study the effect of liquid flow rate on the film boiling heat transfer during reflood using a 6 × 6 heater rod bundle with a full-height heated length. The flooding rate was in the range of 2–30cm/s. The obtained data were evaluated through assessment and improvement of Murao-Sugimoto heat transfer coefficient correlation, which predicted well the heat transfer coefficient under the core flooding rate up to 10 cm/s, but underestimated the heat transfer coefficient in the range of the flooding rate higher than 10 cm/s. An empirical correction factor for the Murao-Sugimoto correlation was proposed based on the present experimental data. The proposed correction factor was confirmed to be applicable to another large scale tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.