Abstract

An experiment was performed in a wide range of core flooding rate to study the effect of liquid flow rate on the film boiling heat transfer during reflood using a 6 × 6 heater rod bundle with a full-height heated length. The flooding rate was in the range of 2–30cm/s. The obtained data were evaluated through assessment and improvement of Murao-Sugimoto heat transfer coefficient correlation, which predicted well the heat transfer coefficient under the core flooding rate up to 10 cm/s, but underestimated the heat transfer coefficient in the range of the flooding rate higher than 10 cm/s. An empirical correction factor for the Murao-Sugimoto correlation was proposed based on the present experimental data. The proposed correction factor was confirmed to be applicable to another large scale tests.