Abstract
To analyze the effect of pulp-capping materials and resin composite light activation on strain and temperature development in the pulp and on the interfacial integrity at the pulpal floor/pulp-capping materials in large molar class II cavities. Forty extracted molars received large mesio-occlusal-distal (MOD) cavity bur preparation with 1.0 mm of dentin remaining at the pulp floor. Four pulp-capping materials (self-etching adhesive system, Clearfil SE Bond [CLE], Kuraray), two light-curing calcium hydroxide cements (BioCal [BIO], Biodinâmica, and Ultra-Blend Plus [ULT], Ultradent), and a resin-modified glass ionomer cement- (Vitrebond [VIT], 3M ESPE) were applied on the pulpal floor. The cavities were incrementally restored with resin composite (Filtek Z350 XT, 3M ESPE). Thermocouple (n=10) and strain gauge (n=10) were placed inside the pulp chamber in contact with the top of the pulpal floor to detect temperature changes and dentin strain during light curing of the pulp-capping materials and during resin composite restoration. Exotherm was calculated by subtracting postcure from polymerization temperature (n=10). Interface integrity at the pulpal floor was investigated using micro-CT (SkyScan 1272, Bruker). The degree of cure of capping materials was calculated using the Fourier transform infrared and attenuated total reflectance cell. Data were analyzed using one-way analysis of variance followed by the Tukey test (α=0.05). Pulpal dentin strains (μs) during light curing of CLE were higher than for other pulp-capping materials ( p<0.001). During resin composite light activation, the pulpal dentin strain increased for ULT, VIT, and CLE and decreased for BIO. The pulpal dentin strain was significantly higher during pulp-capping light activation. The temperature inside the pulp chamber increased approximately 3.5°C after light curing the pulp-capping materials and approximately 2.1°C after final restoration. Pulp-capping material type had no influence temperature increase. The micro-CT showed perfect interfacial integrity after restoration for CLE and ULT; however, gaps were found between BIO and pulpal floor in all specimens. BIO had a significantly lower degree of conversion than ULT, VIT, and CLE. Light curing of pulp-capping materials caused deformation of pulpal dentin and increased pulpal temperature in large MOD cavities. Shrinkage of the resin composite restoration caused debonding of BIO from the pulpal floor.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have