The article presents the results of studying the effect of lanthanum, cerium and praseodymium additives (0–1.0 wt.%) as structure modifiers on the anodic behavior of the aluminum conductive alloy AlTi0.1 in the NaCl electrolyte medium. The studies were carried out using the potentiostatic method with a potential scan rate of 2 mV/s. It was found that over time, the free corrosion potential of the alloys shifts to the positive side and acquires a positive value with an increase in the modifier concentration (lanthanum, cerium, praseodymium) in the aluminum conductive alloy. The addition of lanthanum to the aluminum conductive alloy AlTi0.1 by 12–23%, cerium by 20–30% and praseodymium by 25–35% increases its corrosion resistance. An increase in the corrosion rate of the alloys with an increase in the NaCl concentration in the solution, regardless of their composition, was noted. An increase in the concentration of chloride ion in the NaCl electrolyte leads to a decrease in the potentials of free corrosion, repassivation and pitting of alloys.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.