Abstract

This paper presents results of experimental studies carried out with a Mather type plasma focus device of 2.2 kJ energy. A critical effect of plasma focus inner electrode, IE length on the plasma focus action is detected for IE length has been changed to 9.5, 10.5 and 11.5 cm respectively; also for different Argon gas pressure ranging from 0.2 to 1.8 Torr. To verify this effect, it is important to investigate the plasma focus characteristics such as, a focusing time, voltage spike amplitude, focus action intensity, focus duration time, plasma focus inductance, and radius of plasma focus column as well as pinching ratio.The diagnostics used in the experiments include a Rogowski coil and resistive high voltage probe to measure the discharge current and voltage signals respectively. All the results illustrated that, the best focus action has been achieved for IE length of 10.5 cm and at filling Argon gas pressures varied from 0.8 to 1.2 Torr.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.