Abstract

This randomized split-mouth clinical trial investigated the influence of implant macrogeometry on bone properties and peri-implant health parameters during the healing process. Ninety-nine implants were placed bilaterally in posterior mandibles of 23 patients that received at least four dental implant macrogeometries: standard geometry, Integra (IN) and three geometries inducing "healing chamber": Duo (D), Compact (C), and Infra (IF). Insertion torque (IT) and implant stability quotient (ISQ) were measured. Peri-implant health were monitored by visible plaque index (VPI), peri-implant inflammation (PI), and presence of calculus (CC). Data were collected during 90days. Data were assessed for normality using the asymmetry and kurtosis coefficients followed by the Shapiro-Wilk test. A one-way ANOVA was used to investigate differences in IT and linear bone dimensions between the macrogeometry groups. The repeated measurements ANOVA test or ANOVA-R was used for analysis of ISQ, VPI, and PI. Tukey-Kramer test or Student's t test was used for comparisons between the groups or within each macrogeometry. Macrogeometry did not significantly influence IT and ISQ values. The minimum ISQ was recorded after 7days (71.95 ± 12.04, p = 0.0001). Intermediate ISQ was found after 14days, whenthe ISQ reached values that are statistically identical to primary stability. The VPI showed significantly higher scores for the D (0.88 ± 1.03) and IN (0.72 ± 0.94) implants after 7days. The PI was only influenced by the healing time significantly decreasing from 7 (1.07 ± 0.89) to 21days (0.18 ± 0.18). Implant macrogeometry did not influence IT nor ISQ values. The relationship between IT and SS was more evident for the Duo implant, but only in the final stage of healing process. Show to the clinician that the macrogeometry and drilling protocols did not interfere in the clinical behavior of the implants during the healing process. However, the IT, primary and secondary stability, is quite dependent of the surgeon experience.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.