Abstract

Carbon fiber preforms were pre-heat treated at 2100°C and then filled with smooth laminar (SL) pyrocarbon matrix by isothermal chemical vapor infiltration. The microstructure and flexural properties of carbon/carbon (C/C) composites after heat treatment from 1800 to 2500°C were investigated. The microstructure investigation indicated that heat treatment did not affect the extinction angle, but resulted in distinct interfacial cracks and concentric cracks in the SL pyrocarbon. Three-point bending tests revealed that the flexural strength of the C/C composites decreased rapidly from 221 to 108MPa after treated at 2100°C. This can be explained that the multiple interfacial debonding and concentric cracks lead to poor stress transfer capabilities and high stress concentration. The flexural strength increased back to 126MPa when the composites were heat treated under a higher temperature at 2500°C. This phenomenon was attributed to cracks bridging in the debonding region and the thin high-textured layer at the fiber-matrix interface.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.