Abstract

Herein, the effect of amino acid Glutathione (GSH) on Peroxyoxalate Chemiluminescence was studied for the first time. Hypericin (HYP) was employed as the efficient fluorophore. The investigated parameters included rise and fall rate constant for the chemiluminescence burst, theoretical and experimental maximum intensity, the time-needed to reach maximum intensity and the total light yield emission which theoretically was evaluated using the pooled intermediate model by a computerized non-linear least-squares curve fitting program (KINFIT). Furthermore, based on observed quenching effect of GSH, the Stern–Volmer plot in quencher concentration range of 2.8×10−6 to 3.4×10−5M with KQ value of 1.59×104 was calculated. The bimolecular quenching rate constant (Kq) was also estimated about 2.8×1012 and M−1S−1. Moreover the system was applied successfully to determine glutathione in biological samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.