Abstract
Abstract The sealing gaskets of multistage centrifugal pumps are prone to wear during operation. This study investigates the influence of gasket wear rate on hydraulic performance and internal flow field through numerical simulations. As the wear rate of the gasket increases, both the efficiency and head coefficient of the pump gradually decrease. When the gasket is completely worn out, the efficiency decreases by 5.6% and the head coefficient decreases by 9.5% compared to the unworn gasket condition. Analysis of the internal flow field reveals that the front side chamber is most significantly affected by gasket wear. As the gasket wears, the flow velocity within the front side chamber increases gradually, and the high-entropy production zone expands, thereby affecting the hydraulic performance of the pump. The findings of this study provide practical engineering insights for enhancing the operational performance of multistage centrifugal pumps.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.