Abstract

The influence of downward vapor stream on the falling film evaporation with nucleate boiling outside a horizontal enhanced tube bundle arrayed in a vertical column is experimentally investigated. The variations in local and bundle averaged heat transfer coefficients with vapor velocity are presented. To simulate the practical condition in a falling film evaporator, the flow passages of the liquid/vapor are constructed using two quartz glass sheets and two columns of dummy half tubes. The test ranges are saturation temperature of 6 °C, film flow rate of 0.035–0.1 kgm–1s–1, heat flux of 20, 30, 40 kWm–2. It is found that (1) the downward vapor effects are either positive or negative depending on the tube position, film flow rate, heat flux and vapor velocity; (2) the bundle effect becomes stronger under the effect of downward vapor stream; (3) the downward vapor has a significant effect on the heat transfer of the lower tubes than the upper tubes; and (4) the vapor stream effect on the bundle averaged heat transfer coefficient varies with the levels of film flow rate and heat flux. The experimental results provide significant guidance in the design of the vapor escape channel in a falling film evaporator.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.