Abstract

Massive ingress of air into the core of a high-temperature gas cooled reactor is among the accidents with a low occurrence frequency, but there are still gaps in understanding with respect to its consequences. In the present paper, massive air ingress combined with a delayed start of the afterheat removal system is investigated and compared to air ingress, accidents with normal operation of the afterheat removal procedure. A computer programme REACT/THERMIX used for these accident analyses is described. For a high-temperature gas cooled reactor with a pebble bed core, it is shown that massive air ingress has no real safety endangering consequences even if the operation of the afterheat removal system is delayed by 6 h.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.