Abstract

The elastic mechanical parameters of initial and pre-twisted copper wires were investigated with the aid of a self-developed micro-torsion tester. It was found that the apparent elastic shear modulus and the apparent Young tensile modulus of the copper wires decrease by 13.3 and 8.4% after pre-twist deformation, respectively. In addition, the indentation modulus also decreases as the deformation is increased. When the deformation is more than 30%, the indentation modulus of pre-twisted copper wires is smaller than that of initial copper wires. Microstructural analyses show that the elastic modulus decreases with the proportion of faults.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.