Abstract

To study the effect of contact lens fundus biomicroscopy on the clarity of subsequent fluorescein angiography, the authors compared the fluorescein angiogram from 20 eyes recently examined using a fundus contact lens with fellow control eyes. Saline solution was used to couple the lens to the cornea. In 15 (75%) of the 20 pairs of eyes studied, there was no difference in the fluorescein angiogram clarity between examined and control eyes. In five (25%) patients, there was a slight asymmetry in clarity between the examined and control eyes, but this did not affect the ability to interpret the angiogram. The results were verified by comparing the overall quality of the transit phase of the angiograms. The application of a fundus contact lens to the cornea using saline solution as a coupling agent does not adversely affect the clarity of subsequent fluorescein angiography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.