Abstract

PurposeIn this paper, the authors aim to study the relationship between hydrogen embrittlement (HE) susceptibility and cathodic current density applied on the X70 steel girth welds.Design/methodology/approachThe HE susceptibility of X70 steel girth welds were investigated through slow strain rate tensile test and observed and analyzed by optical microscope and scanning electron microscope methods.FindingsThe results show that HE susceptibility of X70 girth weld was basically unchanged with increasing of ion concentration while gradually increased and maintain at a specific value with the increase of cathodic current density. As for same ion content, a dense calcareous deposit layer generated on the sample surface in soil simulation solution with Ca2+ and Mg2+ resulted a decreased HE susceptibility while the porous calcareous deposit layer resulted a increased HE susceptibility.Originality/valueA logistic regression model was established to describe the correlation between HE index and the cathodic current density.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.