Abstract

Abstract After starting the austempering nucleation of bainitic ferrite was observed within a very short time. Samples that austempered for 2 min.showed martensite in the microstructure. By increasing the austempering time from 30 min to 90 min the retained austenite decomposes and X-ray diffraction observations revealed the greatest volume fraction of retained austenite up to 17.3 and 23.8 percent when austempered for 30 min. Micro-hardness of the bainitic ferrite increased up to 370 and 500 HV and micro-hardness of the retained austenite increased up to 300 and 400 HV at the austempering temperatures of 300°C and 400°C respectively. In comparison to austempered ductile iron, the austempered compacted graphite cast iron shows higher rate of bainitic reaction. Bainite formation driving force and consequently the rate of austempering process are higher in compacted graphite cast irons.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.