Abstract
This study aimed to evaluate the effects of aortic valve opening patterns on endothelial functions in patients undergoing continuous-flow left ventricular assist device (CF-LVAD) implantation. This study included 43 patients who underwent CF-LVAD implantation and 35 patients with heart failure reduced ejection fraction (HFrEF; control group). The CF-LVAD group was divided into three subgroups based on aortic valve opening patterns: open with each beat, intermittently opening, and not opening groups. Flow-mediated dilatation (FMD) and pulsatility index (PI) were compared before and 3 months after CF-LVAD implantation. Cardiopulmonary exercise test (CPET) and 6 minute walk test (6-MWT) scores were measured at baseline and follow-up in the CF-LVAD group. The mean FMD and PI of patients in the CF-LVAD group reduced 3 months after implantation. Patients with intermittently opening and not opening aortic valves had worse endothelial function at follow-up. Before and 3 months after implantation FMD% did not significantly differ in patients whose aortic valves were open with each beat (4.72 ± 1.06% vs. 4.67 ± 1.16%, p = 0.135). Pulsatility index changes paralleled FMD changes. Cardiopulmonary exercise test and 6-MWT scores improved after implantation but without significant differences between subgroups. Maintaining normal aortic valve function after CF-LVAD implantation may reduce endothelial dysfunction; however, larger studies are needed for long-term clinical effects.