Abstract

In order to evaluate the feasibility and performance of liquid lead-bismuth eutectic as the heat transfer fluid for thermocline heat storage tanks in solar power systems, we conducted an effect evaluation of filling medium parameters on the integrated operating and mechanical performances of a thermocline tank using liquid lead-bismuth eutectic using the computational fluid dynamics simulation method. Four parameters were evaluated: the porosity, thermal conductivity, specific heat capacity, and equivalent diameter of the filling medium. The results show that the liquid lead-bismuth eutectic tank operated stably. The total charging and total discharging durations were 5.7 h and 5.3 h, respectively, and the discharging efficiency was 91.94%. The effect evaluation results reveal that the discharging thermocline thickness of the liquid heavy metal tank can be decreased by increasing the specific heat capacity of the filling particles, or by decreasing the porosity, thermal conductivity, and equivalent diameter of the filling medium. The total discharging quantity of the tank increased from 2.19 × 1010 J to 3.34 × 1010 J when the specific heat capacity of the filling particles increased from 610.0 J/(kg∙K) to 1010.0 J/(kg∙K), while the other three filling medium parameters had no obvious effect on the total discharging quantity of the tank. The mechanical performance of the tank wall could be improved by decreasing any one of the four evaluated parameters of the filling medium. The results of this paper may serve as a reference for the design of actual liquid heavy metal heat storage tanks in solar power plants.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call