Abstract
Abstract The use of eddy current (EC) arrays to detect damage in sandwich panels, such as disbonding of the carbon fiber reinforced polymer (CFRP) face-sheet to the core, is investigated. It is shown that the array is very sensitive to slight core crush and can readily find small dents and disbonds. At the same time, the eddy current array can look much deeper into the honeycomb to detect defects such as tears. The phase map of the EC signal can be used in some cases to distinguish between different types of damage. EC arrays offer the ability to rapidly scan large areas of CFRP panels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have