Abstract

Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Caliński-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p< 0.001), and the Caliński-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p< 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p< 0.05), whereas the SNR and CNR values were not significantly different (p= 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.