Abstract

The performance of tactile pressure sensors used in centrifuge testing involving pressure measurements of laterally-spreading soils against a large, rigid, foundation element is evaluated. The tactile pressure sensor measurements were consistent with hydrostatic pressures measured by pressure transducers under most testing conditions, and agreed with at-rest geostatic pressures provided that the measurements were made against a rigid surface (i.e., no relative soil-structure movement). However, measured pressures decreased substantially under some conditions when shearing forces were transmitted to the pressure sensors. Dynamic pressures (minima and maxima pressure spikes) measured by the tactile pressure sensors differed from pressures measured by pore pressure transducers and, when uncorrected, they were considered unreliable. A dynamic pressure correction was developed to address this issue. Lastly, a comprehensive verification testing program was recommended for each unique centrifuge test configuration to improve interpretation of pressure sensor output.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.