Abstract

The 190 nm high performance liquid chromatographic photodiode array profiling of the urinary carboxylic acids of the first urine of a newborn affected with isovaleric aciduria afforded an abnormal peak at 27.8 min. This peak was greatly increased in the carboxylic acid profiling of the 14 h urine sample from the same infant. Isolation of this peak by fraction collecting; solvent extraction of the eluent; trimethylsilyl derivatization of the residue and gas chromatographic/mass spectrometric analysis identified the compound as isovalerylglycine. Correlation of the 190 nm absorbance of isovalerylglycine (y) with concentration (x) afforded a least squares curve: y = 476.4x-13.72 (r = 0.99); run-to-run variation 6.92%; day-to-day variation 8.88% with a minimum detectable concentration of 25 micrograms/ml.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.