Abstract
A computer simulation of the dynamics of a magnetized electron beam in composite drift tubes with multiple virtual cathodes is presented. For a single-cavity tube, the value of the limiting current is found to equal that given by an exact formula. For two-and three-cavity tubes, it is revealed that the values of the limiting currents are smaller than those reported previously and that the current diagram may have a different structure. These phenomena are attributed to Pierce instability. The efficiency of microwave generation as a function of injection current is examined. It is established that the efficiency is minimum if the current equals any of the limiting values refined.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have