Abstract

In order to clarify the mechanism by which the lung airway narrows during an asthma attack, dynamic buckling analysis of the wall was conducted. The wall was modeled using a visco-elastic thin-walled circular cylinder of the Voigt model for the planestress state. A governing equation for dynamic buckling was derived, and in the equation, the contraction of smooth muscle was replaced by uniform inward transmural pressure. The non-dimensional parameters for the buckling wave number n were nondimensional retardation time τ, non-dimensional increasing velocity of inward transmural pressure β, thickness radius ratio α2, radius length ratio η, density ratio ζ, and Poisson's ratio ν. The validity of the theoretical model was confirmed by comparing the calculated wave number with that obtained from the experiment, in which a silicone rubber tube blended with silicone potting gel was used as the in vitro airway model. In addition, the wave number n increased with β. It was necessary to consider the damping effect of the tube model or the airway wall, and n increased by 1.5 to 2 due to the additional mass effect of surrounding tissues of the basement membrane in the airway wall.