Abstract

PurposeTo evaluate the accuracy of a low-dose first-pass analysis (FPA) CT pulmonary perfusion technique in comparison to fluorescent microsphere measurement as the reference standard.MethodThe first-pass analysis CT perfusion technique was validated in six swine (41.7 ± 10.2 kg) for a total of 39 successful perfusion measurements. Different perfusion conditions were generated in each animal using serial balloon occlusions in the pulmonary artery. For each occlusion, over 20 contrast-enhanced CT images were acquired within one breath (320 x 0.5mm collimation, 100kVp, 200mA or 400mA, 350ms gantry rotation time). All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for the FPA measurement. Both MSM and FPA perfusion measurements were then compared to the reference fluorescent microsphere measurements.ResultsThe mean lung perfusion of MSM, FPA, and microsphere measurements were 6.21 ± 3.08 (p = 0.008), 6.59 ± 3.41 (p = 0.44) and 6.68 ± 3.89 ml/min/g, respectively. The MSM (PMSM) and FPA (PFPA) perfusion measurements were related to the corresponding reference microsphere measurement (PMIC) by PMSM = 0.51PMIC + 2.78 (r = 0.64) and PFPA = 0.79PMIC + 1.32 (r = 0.90). The root-mean-square-error for the MSM and FPA techniques were 3.09 and 1.72 ml/min/g, respectively. The root-mean-square-deviation for the MSM and FPA techniques were 2.38 and 1.50 ml/min/g, respectively. The CT dose index for MSM and FPA techniques were 138.7 and 8.4mGy, respectively.ConclusionsThe first-pass analysis technique can accurately measure regional pulmonary perfusion and has the potential to reduce the radiation dose associated with dynamic CT perfusion for assessment of pulmonary disease.

Highlights

  • The advent of quantitative computed tomography (CT) imaging techniques has enabled better evaluation of pulmonary disease

  • The maximum slope model (MSM) (PMSM) and first-pass analysis (FPA) (PFPA) perfusion measurements were related to the corresponding reference microsphere measurement (PMIC) by PMSM = 0.51PMIC + 2.78 (r = 0.64) and PFPA = 0.79PMIC + 1.32 (r = 0.90)

  • The first-pass analysis technique can accurately measure regional pulmonary perfusion and has the potential to reduce the radiation dose associated with dynamic CT perfusion for assessment of pulmonary disease

Read more

Summary

Introduction

The advent of quantitative computed tomography (CT) imaging techniques has enabled better evaluation of pulmonary disease. CT perfusion techniques such as the maximum slope model (MSM), derive pulmonary blood flow by monitoring the contrast enhancement over time using several small volumes-of-interest (VOIs) [13]. This approach can be limited by short contrast transit time (

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call