Abstract

This work addresses two ways of loading proteins on microchannel surfaces for immunoassay applications: the "stop-flow" and the continuous flow processes. The "stop-flow" method consists of successive static incubation periods where the bulk solution depletes upon the adsorption process. In the present paper, a multi-step "stop-flow" protein coating is studied and compared to a coating under continuous flow conditions. For the "stop-flow", a non-dimensional parameter is here introduced, indicating the adsorbing capacity of the system, by which it is possible to calculate the number of loads necessary to reach the optimum coverage. For the continuous flow, the effects on the adsorption of the kinetic rates, flow velocity and wall capacity have been considered. This study shows the importance of a careful choice of the fluid velocity to minimise the sample waste. For diffusion controlled and kinetics controlled processes, two flow velocity criteria are provided in order to obtain the best possible coverage, with the same amount of sample as with the "stop-flow".

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.