Abstract

This paper investigates the deadbeat current controllers for isolated bidirectional dual-active-bridge dc-dc converter (IBDC), including the peak current mode (PCM) and middle current mode (MCM). The controller uses an enhanced single phase shift (ESPS) modulation method by exploiting pulse width as an extra control variable in addition to phase shift ratio. The control variables for PCM controllers are derived in detail and the two different current controllers are compared. A double-closed-loop control method is then employed, which could directly control the high-frequency inductor current and eliminate the transient DC current bias of the transformer. Furthermore, load feedforward was introduced to further enhance the dynamic of the converter. With the proposed control method, the settling time could be reduced within several PWM cycles during load disturbance without transient DC current bias. A 5 kW IBDC converter prototype was built and the settling time of 6 PWM cycles during load change with voltage regulation mode was achieved, which verifies the superior dynamic performance of the control method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.