Abstract

Dynamic economic load dispatch is an extension of the conventional static economic load dispatch which takes into account the ramp rate of generating units. This paper proposes a dynamic economic load dispatch method based on the feasible operation region approach. The region defines how generating units may change their outputs in order to match a demand profile. It is defined by physical and ramp rate constraints of generating units and supply-demand balance constraint. The proposed method has been successfully tested on a 3 generator system supplying a typical afternoon demand profile.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.