Abstract

Saving human lives and cultural heritage from natural disasters is a key to earthquake-disaster mitigation strategies. Culturally valued structures built before earthquake codes and regulations emerged are often vulnerable to earthquake loads, but such structures must be comprehensively studied before applying mitigation measures. Microtremor measurements in Patan Durbar Square area, a World Heritage site, were investigated to determine dynamic properties of the soil at four locations and the predominant ground frequency calculated to be 2.07 Hz. Ambient vibration in an old masonry building was measured and vibration frequencies in different modes were detected using the Fourier spectrum, which found that the building has fundamental period in transverse direction. The building’s damping was estimated to be 5.2-6.4%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.