Abstract

The Milan Cathedral, constructed over a period of more than 400 years, is one of the few Gothic cathedrals where permanent metallic tie-rods are installed under all naves to support a portion of the lateral thrust exerted by vaults and arches. After the recent failure of one tie-rod, an extensive research program was carried out to characterize the metallic material and to evaluate the axial forces and the tensile stresses of the tie-rods through dynamic testing and system identification. After a description of the methodology adopted in the dynamic assessment of tie-rods in the Milan Cathedral, the paper presents the main results of the investigation, in terms of fundamental frequencies and axial forces in the tie-rods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.