Abstract
The purpose of this study is to obtain one of the important dynamical properties, namely natural frequency (ω) for a number of tall buildings with tube and tapered tube systems. Furthermore, it presents an approximate method to analyze the free vibration of tall buildings by tube, tube-in-tube, bundled tube, and tapered tube structures. The method we have proposed would enable us to compute the natural frequency of tubular vertical and tapered tall buildings by the help of computer programming. The models were analyzed by finite element and analytical methods. The results indicate that the investigated analytical method correctly calculates the natural frequency and is in decent accord with the finite element results and has better compatibility with tapered structures without angle with higher altitude. The resulting computational error is very low. Also, this analytical method has the least error for tube systems and the highest error is for tube-in-tube systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.