Abstract
The diagnostic upper port plug in ITER is a long metal box cantilevered to the vacuum vessel port with 42 × M52 studs and nuts. The plug structure has a heavy payload at the front, such as the diagnostic first wall and the diagnostic shield module to protect the diagnostic components from plasma and neutron fluxes. This kind of structural configuration is susceptible to a resonance with the transient external load. For the upper port plug, the design-driving load is electromagnetic (EM) forces due to plasma disruptions. In this paper, the dynamic amplification factor (DAF) of the structure is calculated for such EM loads. The bolted joint at the back flange of the plug structure is also considered together with the port extension of the vacuum vessel and its influence on the dynamic behavior is investigated. The analysis results show that the bolted joint reduces the DAF as well as the natural frequency of the structure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.