Abstract

We demonstrate the application of a high-sensitivity alignment method called interferometric-spatial-phase imaging (ISPI) to a nanometer-level overlay in fluid-immersion lithography, using step-and-flash imprint lithography as the test vehicle. As a stringent test we used alignment marks that consist of pure phase gratings in a fused silica template, immersed in a fluid of similar refractive index, resulting in a low-contrast alignment signal. Feedback control of alignment is demonstrated with mean=0.0nm and σ=0.1nm using an immersed template. Overlay results, with UV-exposed imprint fluid, were limited to ∼4nm, due to a mechanical disturbance. Because ISPI enables continuous monitoring of the alignment signal, we were able to identify the origin of the mechanical disturbance and can eliminate it in future experiments. In addition, we demonstrate the ability to actively reduce misalignment during the progression of crosslinking in the imprint fluid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.