Three-phase Induction Motor (IM) drives are widely used in industrial equipments. One of the essential problems of 3-phase IM drives is their high speed and torque pulsation in the fault conditions. This paper shows Direct Torque Control (DTC) strategy for vector control of a 3-phase IM under open-circuit fault. The objective is to implement a solution for vector control of 3-phase IM drives which can be also used under open-phase fault. MATLAB simulations were carried out and performance analysis is presented. DOI: http://dx.doi.org/10.11591/telkomnika.v13i2.6910 Full Text: PDF

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.