Abstract

This paper presents the comparison of unipolar multicarrier Pulse Width Modulation (PWM) techniques for the Cascaded Multi Level Inverter (CMLI). Due to switch combination redundancies, there are certain degrees of freedom to generate the five level AC output voltage. This paper presents the use of Control Freedom Degree (CFD) combination. The effectiveness of the PWM strategies developed using CFD are demonstrated by simulation and experimentation. The simulation results indicate that the chosen five level inverter triggered by the developed UISCPSPWM and UISCVFPWM strategy with sine and stepped wave references and UISCAPODPWM strategy with THI PWM and 60 degree reference exhibis reduced harmonics. UISCCOPWM provides higher fundamental RMS output voltage for all four chosen references. PWM strategies developed are implemented in real time using dSPACE/Real Time Interface (RTI). The simulation and experimental outputs closely match with each other validating the strategies presented

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.