Abstract

The performance of the drying chamber of a solar assisted drying system was analyzed. The solar assisted drying system consists of drying chamber, V-groove collector of 13.8 mð area, the auxiliary heater and two variable speed centrifugal fans. K-type thermocouples were used for temperature measurement, while solar radiation was measured by Eppley Pyranometer. Drying temperature is considered the most important factor in the drying operation. The accuracy of the temperature measurement is important in this analysis. The procedure for calculating the heat losses from drying chamber may be quite complex and often difficult to accurately determine the numerous variables. In this work standard equations under steady state condition were used to calculate the drying chamber efficiency and the heat losses from the chamber room.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.