Abstract
A 70-MA, 7-MV, ∼100-ns driver for a Z-pinch Inertial Fusion Energy (Z-IFE) power plant has been proposed. In this summary we address the transition region between the 70 Linear Transformer Driver (LTD) modules and the center Recyclable Transmission Line (RTL) load section, which convolves from the coaxial vacuum Magnetically Insulated Transmission Lines (MITL) to a parallel tri-plate and then a bi-plate disk feed. An inductive annular chamber terminates one side of the tri-plate in a manner that preserves vacuum and electrical circuit integrity without significant energy losses. The simplicity is offset by the disadvantage of the chamber size, which is proportional to the driver impedance and decreases with the addition of more parallel modules. Inductive isolation chamber sizes are estimated in this paper, based on an optimized LTD equivalent circuit simulation source driving a matched load using transmission line models. We consider the trade-offs between acceptable energy loss and the size of the inductive isolation chamber; accepting a 6% energy loss would only require a 60-nH chamber.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.