Abstract

This report presents the performance of drift chambers operated in the limited streamer mode with 9.4 cm maximum drift distance and position sensing along the 4.35 m long anode wire through delay line timing. Using only three timing channels a position resolution of 1×3 mm 2 is obtained over a detector surface of 19×435 cm 2. In this contribution, the emphasis is mainly put on the performance of the delay line and on the drift behaviour in streamer mode using safe gas mixtures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.