Abstract
To compare the precision of tibial plateau leveling osteotomy (TPLO) surgery when performed with or without a jig. Cadaveric study. Cadaveric, adult greyhound hindlimbs (n=9 pair). TPLO (n=18) was performed on each limb pair; 1 with and 1 without use of a jig. Measurements taken from pre- and postsurgical radiographs were osteotomy position, tibial plateau angle (TPA), varus-valgus malalignment, and tibial torsion. The null hypothesis was that TPLO precision was not affected by use of a jig. Student's t-test was used to investigate differences in TPA, osteotomy location, and frequency and extent of iatrogenic limb malalignment; P<.05 was considered significant. There were no significant differences in postsurgical TPA, tibial crest thickness, varus-valgus malalignment, or tibial torsion between TPLOs performed with or without a jig. Osteotomy location was significantly more distal when a jig was used (P=.03). Jig use did not improve the precision of TPLO surgery. Performing TPLO without a jig should reduce surgery time, eliminate complications related to placement of the distal jig pin and allow unhindered positioning of the osteotomy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.