Abstract

BackgroundThe new generation thinner-strut silicon carbide (SiC) coated cobalt chromium (CoCr) bare-metal stents (BMS) are designed to accelerate rapid endothelialisation and reduce thrombogenicity when implanted in coronary arteries. However, smaller studies suggest higher rates of symptomatic restenosis in patients receiving the newer generation BMS.We investigated the efficacy of a newer generation ultrathin strut silicon-carbide coated cobalt-chromium (CoCr) BMS (SCC-BMS) as compared to an older thin-strut uncoated CoCr BMS (UC-BMS) in patients presenting with coronary artery disease requiring stenting of large vessels (≥3.0 mm).MethodsAll patients randomized to SCC- (n = 761) or UC-BMS (n = 765) in the two BASKET-PROVE trials were included. Design, patients, interventions and follow-up were similar between trials except differing regimens of dual antiplatelet therapy. The primary endpoint was clinically driven target-vessel revascularization within 24 months. Safety endpoints of cardiac death, non-fatal myocardial infarction (MI), and definite/probable stent thrombosis (ST) were also assessed. We used inverse probability weighted proportional hazards Cox regressions adjusting for known confounders.ResultsDemographics, clinical presentation, and risk factors were comparable between the groups, but patients receiving SCC-BMS underwent less complex procedures. The risk for clinically driven TVR was increased om the SCC-BMS group compared to the UC-BMS group (cumulative incidence, 10.6% vs. 8.4%; adjusted relative hazard [HR], 1.49 [95% CI, 1.05–2.10]). No differences in safety endpoints were detected, cardiac death (1.6% vs. 2.8%; HR, 0.62 [CI, 0.30–1.27]), non-fatal MI (3.2% vs. 2.5%; HR, 1.56 [CI, 0.83–2.91]), and definite/probable ST (0.8% vs. 1.1%; HR, 1.17 [CI, 0.39–3.50]). Differences in strut thickness between the two stents did not explain the association between stent type and clinically driven TVR.ConclusionsIn patients requiring stenting of large coronary arteries, use of the newer generation SCC-BMS was associated with a higher risk of clinically driven repeat revascularization compared to the UC-BMS with no signs of an offsetting safety benefit.

Highlights

  • The new generation thinner-strut silicon carbide (SiC) coated cobalt chromium (CoCr) bare-metal stents (BMS) are designed to accelerate rapid endothelialisation and reduce thrombogenicity when implanted in coronary arteries

  • Initial findings from clinical registries were promising with rates of target-lesion revascularization (TVR) below 5% at 6 months [5, 6] subsequent observational analyses using an established uncoated CoCr BMS as comparator demonstrated higher rates of TVR at 12 and 18 months [7, 8]

  • The randomized, multicenter BAsel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination (BASKET-PROVE) and BASKET-PROVE II trials provide a unique opportunity for studying this relation in patients with large coronary arteries, who a priori have a lower risk of symptomatic restenosis, at 24 months follow-up

Read more

Summary

Introduction

The new generation thinner-strut silicon carbide (SiC) coated cobalt chromium (CoCr) bare-metal stents (BMS) are designed to accelerate rapid endothelialisation and reduce thrombogenicity when implanted in coronary arteries. We investigated the efficacy of a newer generation ultrathin strut silicon-carbide coated cobalt-chromium (CoCr) BMS (SCC-BMS) as compared to an older thin-strut uncoated CoCr BMS (UC-BMS) in patients presenting with coronary artery disease requiring stenting of large vessels (≥3.0 mm). The new generation ultrathin-strut cobalt-chromium (CoCr) bare-metal stents (BMS) with a passive silicon carbide coating were designed to rival modern DES through reduced rates of in-stent restenosis [4]. We investigated the efficacy of a new generation ultrathin strut silicon-carbide coated CoCr BMS (SCC-BMS) as compared to an older thin strut uncoated CoCr BMS (UC-BMS) in patients with coronary artery disease requiring stenting of large vessels (≥3.0 mm) The randomized, multicenter BAsel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination (BASKET-PROVE) and BASKET-PROVE II trials provide a unique opportunity for studying this relation in patients with large coronary arteries, who a priori have a lower risk of symptomatic restenosis, at 24 months follow-up.

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call